**Note:&#x20;**&#x54;he LTS release 2.32.2 is compatible with both MDE 1.4.x and 1.5.x.
:::

The following limitations have been identified. When they are resolved, they will be reported in the latest [Product Updates](docId\:l01ha-kIVrLWEtWhZy0qb) under *Resolved Issues*.&#x20;

| Description                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                       |
| --------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- |
| **Edge Devices:**<br />* There may be issues when trying to create a backup for an edge device.&#x20;                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                             |
| **Templates:**<br />* No notification appears when creating a template from a Manufacturing Connect Edge device with a trial license.                                                                                                                                                                                                                                                                                                                                                                                                                                                                                             |
| **Applications:**<br />* When cloning a Marketplace application release to the latest version tag, the application container stops and must be manually restarted. As a workaround, create a new application release configuration and submit the release instead of cloning.                                                                                                                                                                                                                                                                                                                                                     |
| **System**:<br />* Some devices may fail to backup with a `409 couldn't upload backup: couldn't get upload URL: unexpected response` message when performing a backup to the cloud from Manufacturing Connect Edge (in **System** > **Device Management** > **Backup/Restore**). As a workaround, upload the backups manually to Manufacturing Connect.
* Upgrading Manufacturing Connect directly from version 2.16.7 to 2.31.1 may fail with a `Failed to stop lem-admin-healthcheck.timer: Unit lem-admin-healthcheck.timer not loaded` error.
* You may not be able to successfully archive files that are larger than 700MB. |