---
title: Industrial Systems Connection Guide
slug: manufacturing-connect-edge-v1/industrial-systems-connection-guide
docTags: 
createdAt: 2022-03-30T21:25:29.000Z
---

Refer to the following configuration settings for specific devices when you [Connect a Device](docId\:RFVIJdxz7DBAd8mwbismA). &#x20;

- [ABB](docId\:c8fGw-doqyD-UQK8GH_ao)&#x20;
- [Atlas Copco](docId:04wB4nOwx3eLIQhxOaCBN)&#x20;
- [Allen-Bradley](docId\:OVgBTB4hMRBn99eCiUjYF)&#x20;
- [BACnet](docId:6qNqTn50aQhlx-F5twqPc)&#x20;
- [Beckhoff](docId\:DVBR-F-hEK9H-jNIl8pRn)&#x20;
- [Brother Industries Ltd](docId\:RPVmD9y0VbQy-J9JOwMKZ)&#x20;
- [CAN Bus](docId\:SaIzGUL7k0j_FZe4ZsnhT)&#x20;
- [CodeSys Devices](docId\:xyYI3Vev6daw8VdwxENmo)&#x20;
- [Cutler-Hammer](docId\:I-Ibnt6xnNRcV-6JoDn1Y)&#x20;
- [Danfoss](docId\:DMtE1kgxTLpb0M2v9GJ4m)[Danfoss](docId:4VlmhrHNe-GSTwbONvm_P)&#x20;
- [Delta PLC](docId\:JhA1Q-M16LcxNtrMSd5OY)&#x20;
- [Emerson](docId:2r5ZkTqNi-41JPcPpgIMy)&#x20;
- [Euromap63](docId:7wHzo_ugOg9tzHgOQdljJ)&#x20;
- [Excel](docId\:KPcyZWMzVkX2FGrAKVXCb)
- [Fanuc Corporation](docId:_pu6yTEwYNMBQyPkvWTLH)&#x20;
- [Fuji Devices](docId\:BV2RLU5OFTnJlsDoPC60Y)&#x20;
- [GE Fanuc](docId\:VHADomh7Ry2v4OgK_LfwH)&#x20;
- [GPIO](docId\:QDuY9n382fa8mY-LNl0al)
- [Heidenhain](docId\:AJs663ZmeDr4dtTl8LXkq)&#x20;
- [HID Devices](docId\:VEcggQ3oAWfiSgsRmNJsk)&#x20;
- [Hitachi Devices](docId:4URFN9R-ItIchXqMiwV0O)&#x20;
- [HPE](docId\:EsF20bUQn9hPhiYn3-t3z)&#x20;
- [IEC](docId\:PtxGafqv0qazVViMNKAiT)&#x20;
- [JTEKT Toyopuc](docId:_1P3rbyAoNAF6KPzF-kYd)&#x20;
- [Keyence](docId\:D2bjg7_uymE5_k0480W3r)&#x20;
- [Koyo](docId\:hi_tvRrYIcqbpBbk0zbj8)&#x20;
- [LS Industrial System](docId:9T6AOUFUsZxazNXn8rIWT)
- [Mitsubishi](docId\:zi0kw_QE5-KmZzM82cWvK)&#x20;
- [Modbus](docId\:Ws1IqJ1juXIuAU_goL1Hi)&#x20;
- [MQTT](docId\:Ilt9PEQh8Q2qyBeirn9TD)
- [MTConnect](docId\:vcx6YsO3-xDmZgey2PpBm)&#x20;
- [ODVA](docId\:qrijYUVaRRMbKRyMfpU1-)
- [ODVA](docId:4BZrPIF1nPjIEmeXkl4jt)&#x20;
- [OPC UA](docId\:GztrXKgIlHGySS3xAXygI)&#x20;
- [Opto Devices](docId\:wlshziPCeSSkI_kQalu4h)
- [OSI Agent](docId\:mxbltmvep6-m7RZRh3UIp)
- [Panasonic](docId\:ux8A41qj7DqMPuGNIBUyx)&#x20;
- [Parker](docId:5Hafe0vbpxcqQ4XT4F2tj)&#x20;
- [Ping](docId\:LDnuxpvJPFL_Xy3RtXe_O)
- [Profinet](docId:_6N4qy1rnBS9SfOO2epj1)&#x20;
- [RS Automation](docId\:oTLFhNTPjBHlROubAfFY0)&#x20;
- [SAIA](docId\:vXb6j5i266gieK4blyw-H)&#x20;
- [Sick Flexi](docId:7KXJNfkHOzs5lvjQQDfDc) &#x20;
- [Siemens](docId\:mIG378moH3-P0nIMhubSM)&#x20;
- [Simulator](docId\:fSh4SXiKltxu6wkSUf2-A)&#x20;
- [Toshiba](docId\:Hv0ZrCX-EoNY8YwErYwAp)&#x20;
- [VIPA](docId:1fTwiMJXGVSYY7bY6KasS)
- [Yokogawa](docId:-pAZZHODNR0FENY0MTzVH)&#x20;
- [Yaskawa](docId:0yiXlcVeHFo17rY2UZ1-X)&#x20;

# Deprecated Drivers

Refer to the table for drivers that have been deprecated or will be deprecated in a future release. Review the **Recommended Replacement Driver** column for drivers that should be used instead.&#x20;

| **Driver**                                                    | **Recommended Replacement Driver**                                                                                                   | **Version Removed** |
| ------------------------------------------------------------- | ------------------------------------------------------------------------------------------------------------------------------------ | ------------------- |
| [Siemens S7-400 (Gen1)](docId\:Mc7cGQ_5yZkQNSoRDBkdO)         | One of the following:<br />* [Siemens S7](docId\:a50A75g3HxHoTGD8M8S8X)
* [Siemens S7-Advanced (Gen1)](docId\:oBhvOZ2QLZQZHKpvhBjOa) | 3.10.0              |
| [Mitsubishi A2SH Serial (Gen1)](docId\:dKjvR88rffsAuy6xwZAMZ) | [Mitsubishi A Series Serial](docId\:eY1yKKGrOOcmXfn2DMrZy)                                                                           | Future version      |
| [Modbus ASCII (Gen1)](docId\:fbrGDbcmX-trUz_inlTvK)           | [Modbus ASCII](docId\:yS_xifsVRika-wr1DE-WQ)                                                                                         | Future version      |
| [Modbus RTU (Gen1)](docId\:XZO28HbNYsFvXyjWtJf77)             | [Modbus RTU](docId:8Fmimu9YUHT-wNFHSOxIj)                                                                                            | Future version      |
| [Modbus TCP (Gen1)](docId\:ghYw-l8vRPWU43Ld5Vo_m)             | [Modbus TCP](docId:_WkU1najUGa3kzU-g9vTy)                                                                                            | Future version      |
| [Modbus UDP (Gen1)](docId\:JWD_flnf5NdYA8GAiis-l)             | [Modbus UDP](docId\:gDjQd3PXwG4fjjpDS7jHd)                                                                                           | Future version      |
| [Modbus RTU-Offset (Gen1)](docId\:fQlnNEP-z5KkRkrXa5xOi)      | [Modbus RTU](docId:8Fmimu9YUHT-wNFHSOxIj)                                                                                            | Future version      |
| [Modbus TCP-Offset (Gen1)](docId\:wG8bjCmR5z6OiSnb0TcNK)      | [Modbus TCP](docId:_WkU1najUGa3kzU-g9vTy)                                                                                            | Future version      |
| [OPC UA Client](docId\:EHdMTzCERQmqjy9VX1r1S)                 | [OPC UA Client Advanced](docId:_xC_ccjxHDJlmLht1JaJe)                                                                                | Future version      |
| [OPC UA Client Poll](docId\:jBSZZRzXMdUSOolMWzexE)            | [OPC UA Client Advanced](docId:_xC_ccjxHDJlmLht1JaJe)                                                                                | Future version      |

