Quickstart Guide
...
Industrial Systems Connection ...
JTEKT Toyopuc
JTEKT Toyopuc CMP-Link Ethernet (Gen1)
6min
review the following information for setting up and configuring the jtekt toyopuc cmp link ethernet (gen1) driver manufacturing connect edge compatible series compatibility parameter compatible items driver type ethernet validated devices/series jtekt toyopuc pc10 to set up and configure this device in manufacturing connect edge, you will need to do the following step 1 set up and configure the plc device step 2 set up the plc device in manufacturing connect edge devicehub step 3 configure the list of registers step 1 set up and configure the plc device if the device is configured for ethernet access, find its network parameters otherwise, use plc software on your computer to configure the device for ethernet access step 2 set up the plc device in manufacturing connect edge devicehub configure the following parameters when you connect a device docid\ rfvijdxz7dbad8mwbisma with this driver update default values to the specific set up of your device parameter value type jtekt toyopuc driver jtekt toyopuc cmp link ethernet (gen1) network address the device address you defined in step 1 network port 4096 step 3 configure the list of registers when you add tags docid\ ioanzd2awqnkuppgee3eh to the connected device, refer to the following register table and tag parameters refer to the following additional resources organize device and tag data by using metadata docid\ f b720nivllber44rfyhn tag formula variables docid\ pwd 7p kzjxkt pyawaow register table name value type address format min address max address 1x bit hhh 0 2047 2x bit hhh 0 2047 3x bit hhh 0 2047 1y bit hhh 0 2047 2y bit hhh 0 2047 3y bit hhh 0 2047 1m bit hhh 0 2047 2m bit hhh 0 2047 3m bit hhh 0 2047 1k bit hhh 0 2047 2k bit hhh 0 2047 3k bit hhh 0 2047 1l bit hhh 0 2047 2l bit hhh 0 2047 3l bit hhh 0 2047 1v bit hh 0 255 2v bit hh 0 255 3v bit hh 0 255 1t bit hhh 0 2047 2t bit hhh 0 2047 3t bit hhh 0 2047 1c bit hhh 0 2047 2c bit hhh 0 2047 3c bit hhh 0 2047 1s bit hhhh 0 16383 2s bit hhhh 0 16383 3s bit hhhh 0 16383 1n bit hhhh 0 8191 2n bit hhhh 0 8191 3n bit hhhh 0 8191 1d bit hhhhh 0 196607 2d bit hhhhh 0 196607 3d bit hhhhh 0 196607 1r bit hhhhh 0 32767 2r bit hhhhh 0 32767 3r bit hhhhh 0 32767 b bit hhhhh 0 131071 h bit hhhh 0 32767 u bit hhhhhh 0 2097151 ex bit hhh 0 2047 ey bit hhh 0 2047 em bit hhhh 0 16383 ek bit hhh 0 2047 el bit hhh 0 2047 ev bit hhhh 0 16383 et bit hhh 0 2047 ec bit hhh 0 2047 es bit hhhh 0 16383 en bit hhhh 0 16383 gx bit hhhh 0 65535 gy bit hhhh 0 65535 gm bit hhhh 0 65535 eb bit hhhhhh 0 4194303 fr bit hhhhhh 0 2097151 1xw bit hh 0 127 2xw bit hh 0 127 3xw bit hh 0 127 1yw bit hh 0 127 2yw bit hh 0 127 3yw bit hh 0 127 1mw bit hh 0 127 2mw bit hh 0 127 3mw bit hh 0 127 1kw bit hh 0 127 2kw bit hh 0 127 3kw bit hh 0 127 1lw bit hh 0 127 2lw bit hh 0 127 3lw bit hh 0 127 1vw bit h 0 15 2vw bit h 0 15 3vw bit h 0 15 1tw bit hh 0 127 2tw bit hh 0 127 3tw bit hh 0 127 1cw bit hh 0 127 2cw bit hh 0 127 3cw bit hh 0 127 1sw bit hhh 0 16383 2sw bit hhh 0 1023 3sw bit hhh 0 1023 1nw bit hhh 0 511 2nw bit hhh 0 511 3nw bit hhh 0 511 1dw bit hhhh 0 12287 2dw bit hhhh 0 12287 3dw bit hhhh 0 12287 1rw bit hhhh 0 2047 2rw bit hhhh 0 2047 3rw bit hhhh 0 2047 bw bit hhhh 0 8191 hw bit hhh 0 2047 uw bit hhhhh 0 131071 exw bit hh 0 127 eyw bit hh 0 127 emw bit hhh 0 1023 ekw bit hh 0 127 elw bit hh 0 127 evw bit hhh 0 1023 etw bit hh 0 127 ecw bit hh 0 127 esw bit hhh 0 1023 enw bit hhh 0 1023 gxw bit hhh 0 4095 gyw bit hhh 0 4095 gmw bit hhh 0 4095 wt bit h 0 6 ebw bit hhhhh 0 262143 frw bit hhhhh 0 131071 note the count parameter is only available for manufacturing connect edge version 3 11 3 and later tag parameters name select a register name from the drop down list the available options depend on the names in the register table value type select a data type from the drop down list the available options depend on the register name selected polling interval enter a value in seconds this determines how often the tag should poll the register for data tag name enter a name for the tag description (optional) enter a description for the tag address enter a tag address the value must in the decimal format, within the allowed min/max range omit the leading zeros the device might use the decimal (d), hexadecimal (h), or octal (o) address format see the register table at the bottom of the dialog box for bit tags, append the bit address without the bit separator the lowercase letters in the address format indicate how many digits you should enter in the bit address tag formula enter a formula for the tag to process the generated data two variables are permitted value (current tag value) and timestamp (current tag unix time in milliseconds) the following math functions are available sin cos sqrt tan power power( x ) performs the operation 10^x log log( x ) is the natural logarithm (the logarithm is in base e ) exp exp( x ) performs the operation e^x only publish on change of value select the checkbox to customize nats messages to be published only when the value parameter changes from a previous value to a new one change of value only applies to boolean, numeric (such as int or float), and simple string data types it does not apply to complex types, such as json or array poll once topics will not be affected by change of value settings these topics will still only see a single message meta data metadata summarizes basic information about data this feature allows you to define key value pair data for the device output payload later on it can then be used to find, use, and reuse particular instances of data note if you use special characters in meta data key names, the special characters are replaced with underscore characters in the payload this can cause two key names to be combined into one for example, configuring the key names a b and a&\&b will cause only one key name to be created (a b)