Product Features
...
System
Backup/Restore
Manage Templates
9min
you can upload and download device configuration templates by navigating to system > backup/restore from the templates tab template configurations the following component categories are available for selection you can select a whole category, or individual components within a category, for download each category will show the list of component that you have configured or installed on the device for example, the connectors category will show the list of connectors that are on the device auth this includes configurations of ldap/ad authentication providers this doesn't include roles, groups, and users created in manufacturing connect edge see ldap/ad auth docid\ fkudxbnzzcdpebv6kcfv connectors installed connectors and configurations connectors with the same name that exist in both the template and the manufacturing connect edge device will be duplicated with a unique name after uploading the template the default connector that connects manufacturing connect edge and manufacturing connect is not included see integration docid\ fitazsjni lahjv2qcmsn country configured for the instance see access the terminal user interface docid\ nv5 vdiqscyc3uktney38 devices connected devices, tags, and configurations see devicehub docid\ yw3i2nqstczpb pit0j9b dns saved fallback dns resolvers see configure dns/ntp servers docid\ ohe3dlewccqcnqnvmr0eg docker contains the ip address and netmask to use for docker’s default bridge using standard cidr notation see applications docid\ c lhahek2hh3hreyjflrw example "bip" "10 30 50 1/24" firewall saved firewall rules see manage firewall rules docid\ aeo9mcsa8 tbhqqnr5v b flows saved flows see flows manager docid 5bbsox0doib rc iuliim note when you upload a template, the existing flows in the instance are replaced with the flows in the template configuration if you would like to ensure existing flows are maintained after uploading a template, confirm that any flows you want to keep are part of the template configuration analytics groups saved analytics flows and processors within each group see analytics docid\ ijqp0ihd8tue3ntgltufp marketplace installed catalogs and registries only applications deployed using a catalog can be part of a template for example, if you deployed an application from the catalog, it is part of a template file if you use the docker run command to deploy an application, it is not part of a template file see marketplace docid\ xa2ovbmq7fub7yfkisglz ntp saved network time protocol (ntp) servers see configure dns/ntp servers docid\ ohe3dlewccqcnqnvmr0eg and troubleshooting time synchronization docid 7hqvnx0ctnrcwyuwvdbhz opc ua saved configurations see opc ua docid\ gztrxkgilhgyss3xaxygi static routes saved static routes see manage static routes docid\ aans5opzsf1ecpj1rgbfm timezone configured for the instance see access the terminal user interface docid\ nv5 vdiqscyc3uktney38 download a template you can download multiple device configuration templates, selecting different configurations from a single manufacturing connect edge device these device configuration files are then available on your hard drive for upload to other manufacturing connect edge devices the template files can also be uploaded to a manufacturing connect to be applied to groups of manufacturing connect edge devices you can customize the template prior to downloading by selecting components individually or by category before you begin to access the features on the backup/restore page, you need a valid license how to download a template to download a template in manufacturing connect edge, navigate to system > backup/restore the backup/restore pane appears select the template tab the template pane appears from the templates section, select the checkboxes for the configurations you want to include in the device configuration template or select the select all check box click download template a \<date> template json file downloads to your hard drive upload a template note if you upload a template with the same connectors that are already existing in the manufacturing connect edge device, then duplicate connectors will be created with unique names for example, if the template and the manufacturing connect edge device both have a mysql connector with the name mysql integration , a duplicate connector will be created with the name mysql integration (1) for manufacturing connect edge version 3 10 0 and later, if one component fails during a template upload, an error message will display and the upload process will continue with the remaining components you can upload a device configuration template by navigating to system > backup from the templates tab when you upload a device configuration template, it applies the configuration in the file to the manufacturing connect edge device you can also apply templates to manufacturing connect edge devices using manufacturing connect, potentially changing the configurations for hundreds of manufacturing connect edge devices before you begin to access the features on the backup/restore page, you need a valid license download a device configuration template see the download a template section how to upload a template to upload a template in manufacturing connect edge, navigate to system > backup/restore the backup/restore pane appears select the template tab the template pane appears click upload template navigate to a \<date> template json file saved on your hard drive, and then click open the selected template successfully updates in the templates section and applies the configurations to the manufacturing connect edge device note if the upload fails, the error message can only inform failure has occurred it cannot inform which specific template component failed