Review the current list of [Limitations](docId\:DbGc7poxmg63EV8NNrP4Q).&#x20;

## New Features

| Description                                                                                                                                    |
| ---------------------------------------------------------------------------------------------------------------------------------------------- |
| **DeviceHub**:<br />Support is now provided for the following drivers:<br />* Siemens S7 CommPlus Symbolic
* OSI Agent Advanced
* Enron Modbus |

## Enhancements and Improvements

| Description                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                          |
| -------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- |
| **System**: <br />* The Enable Data Store setting for DeviceHub devices is now saved in template files.&#x20;                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                        |
| **DeviceHub**:<br />* New data types are now available for Omron NJ Ethernet (Gen1).&#x20;
* The following options are now available when connecting a device.&#x20;
  - **Publish on Polling Interval**
    - Only available for Gen 2 drivers.&#x20;
    - If this option is selected, the driver will always publish messages according to the polling interval configuration. If the driver has not completed the request to read the data at a polling interval, the payload will have a `success=false` message.&#x20;
    - If this option is not selected, the driver will not publish a message at the polling interval if the request to read data has not completed.&#x20;
  - **Watchdog**
    - This option is not available for all drivers. For example, drivers that act as servers don't have this option, such as Industrial OT Server and OSI Agent.&#x20;
    - If this option is selected, the driver will be monitored based on the Watchdog period (in seconds) you configure. If an issue is detected, then the driver will restart.&#x20;
* The Browse Tags feature is now available for the Beckhoff TwinCAT3 Ethernet(Gen1) driver.&#x20; |
| **Integration**:<br />* The client email parameter is now available for the Google Pub/Sub connector.&#x20;                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                          |

## Resolved Issues

| Description                                                                                                                                                                                                                                                                 |
| --------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- |
| **System**: <br />* Fixed issue with backup files with over 25 DeviceHub devices not uploading successfully.&#x20;                                                                                                                                                          |
| **DeviceHub**:<br />* Fixed issue with the Browse Tags feature returning the incorrect number of tags for the OPC UA Client Advanced driver.&#x20;
* Fixed issue with the Roc800 Ethernet driver crashing after adding a tag with type Opcode180.&#x20;                     |
| **Analytics**:<br />* Fixed navigation issue while configuring the Tengo script processor.&#x20;                                                                                                                                                                            |
| **Flows Manager**: <br />* Fixed issue with Flows Managers displaying a `warning` status incorrectly.&#x20;                                                                                                                                                                 |
| **Integration**:<br />* Fixed issue with frequent disconnections from the InfluxDB 2.x TCP connector.&#x20;
* Fixed issue with the Mindsphere connector not being able to send data.&#x20;
* Fixed issue with the log window not resetting when returning to view it.&#x20; |
| **OPC UA**: <br />* Fixed issue with the OPC UA server showing tags with the bit data type as a string data type.&#x20;
* Fixed issue with importing a hierarchy from DeviceHub from a JSON file and the NodeID Settings are ignored.&#x20;                                 |