Product Features
...
Connections
Add an OPC UA Client Connection
2 min
you can connect a new client to the opc ua server the following procedure uses uaexpert on windows 10 as the example client if you are using the docker version of manufacturing connect edge and having issues connecting to the opc ua server, refer to issues connecting to opc ua server docid\ awrycagzq5pqaypuomob8 before you begin before completing the steps below, make sure you do the following add nodes to the opc ua hierarchy see add a node docid\ dgy3dqxyxt6cfug29cs g or import nodes docid\ cahk4ypj4mro qc1c1apv for more information start the opc ua server see manage the opc ua server docid\ rmrzfn dogy5tzvqlpkqh for more information run your server on port 4840 see manage the opc ua server docid\ rmrzfn dogy5tzvqlpkqh for more information connect a client with uaexpert to connect a client with uaexpert download uaexpert from unified automation https //www unified automation com/downloads/opc ua clients html open uaexpert click the add server button at the top the add server dialog box appears from custom discovery , double click to add a server from the enter url dialog box, enter the manufacturing connect edge ip address with the ocp\ tcp\ // protocol on port 4840 for example ocp tcp\ //192 168 1 130 4840 click ok the ua expert client should automatically discover your opc ua server