You can configure the network interfaces by navigating to **System&#x20;**>**&#x20;Network** > **Interfaces**.&#x20;

![](https://api.archbee.com/api/optimize/SSUUxKZUk9bFTEPNn_6Zo/JyxL8CGhSU73GBV9GRoj-_image.png)

:::hint{type="warning"}
**Caution**: Changing the network address may cause the application to stop working properly.
:::

# Important

The Manufacturing Connect Edge software package installation includes a default configuration for the selected device's interface. You must configure the default entries with your own network information.&#x20;

For IPv4 address assignment type, you can choose from a few different options.

- **None**: Disables IPv4 addresses on the network interface.
- **DHCP**: Auto-assigns an IPv4 address to the network interface.
- **Static**: Manually enter Gateway information for your network interface. Valid Gateways depend on your router configuration.
- **CIDR**: CIDR notation determines which IP addresses are allowed on the network. Entering your Gateway address and **/24** usually suffices because it allows close to 256 different IPv4 addresses, starting from your Gateway address. For example, if 192.168.7.17 is your Gateway, 192.168.7.17/24 denotes a good CIDR because it allows 238 (256 - 18) different IP addresses. For full details about CIDR, see the [CIDR Conversion Table](docId\:VCjK0QdrgJCfNqbhHUss8).&#x20;

For IPv6 address assignment type, you should use *Auto&#x20;*&#x69;nstead of *DHCP&#x20;*&#x74;o automatically assign an IPv6 address.&#x20;

# Before You Begin

Make sure your configuration is using the same network on which your device is located.

# Update Network Interfaces

**To update the network interfaces:**

1. Navigate to **System&#x20;**> **Network**.&#x20;
2. Click the **Interfaces&#x20;**&#x74;ab.&#x20;
3. Review the list of interfaces. Please note the following:
   - Devices are automatically detected by the system and should be listed under Interfaces. The *eth0&#xA0;*&#x63;onfiguration contains the default settings for the WAN (outgoing traffic). Do not change the settings for the WAN.
   - A USB to an Ethernet dongle is not recognized as a device due to security measures.
4. Click **Update&#x20;**&#x66;or an interface.&#x20;
5. Update the details for the interface.&#x20;
   - **WAN**: If the selected interface is *eth0*, select the **WAN&#x20;**&#x63;heck box. Optionally, select the check box if the selected interface is *eth1*.&#x20;
   - **IPv4 Type**: Use the drop-down list to select *None*, *DHCP*, or *Static*.&#x20;
   - **IPv4 Gateway** (Optional): If you select *Static*, enter an IP address range.&#x20;
   - **IPv6 Type**: Use the drop-down list to select *None*, *Auto*, *DHCP*, or *Static*. It is recommended that you use *Auto&#xA0;*&#x69;nstead of *DHCP&#xA0;*&#x74;o automatically assign an IPv6 address.
   - **IPv6 Gateway** (Optional): If you select *Static*, enter an IP address range.&#x20;
6. Click **Update**.&#x20;
7. Reboot your device to apply any changes to network configuration.