title: Input Processors
slug: manufacturing-connect-edge-v2/input-processors
docTags: 
createdAt: 2024-08-08T21:37:32.226Z
---

The Analytics module makes use of built-in Input processors to retrieve data from a topic, database, or generator.&#x20;

The following describes the input processors that are currently available.



# Database Batch Input Processors

## Database Batch Input Overview

- Generate events by periodically polling specified DB measurements.
- **Filtering:**
  - You could add filtering for queries.
  - List of fields depends on database and measurement, but for device data, standard filters are: datatype, device\_id, is\_device\_status, register\_id, success, tag, topic, value.
- **Examples:**
  - Filter by tag: "tag" = 'tag1'
  - Filter by tag and success: "tag" = 'tag1' AND "success" = 1

## Database Batch Input Parameters

| **Parameters** | **Details**                                                                                  |
| -------------- | -------------------------------------------------------------------------------------------- |
| Database       | Select the name of the database from which data will be retrieved.                           |
| Filter         | Specify the SQL filter for the WHERE part of the query to filter the data from the database. |
| Metric Name    | Name of the metric for TimeSeriesDB polling.&#xD;                                            |
| Period Secs    | Set the polling interval in seconds for retrieving data from the database.                   |
| Typed          | Define the data typed policy for processing the retrieved data.                              |

![](https://api.archbee.com/api/optimize/SSUUxKZUk9bFTEPNn_6Zo/cwHzHp4cd5AQAH7BZCD-U_image.png "Database Batch Input parameters")

# DataHub Subscribe Processors

## DataHub Subscribe Overview

- Generate events from specified DataHub topic and attach to output.

## DataHub Subscribe Parameters

| **Parameters**                                                            | **Details**                                                                      |
| ------------------------------------------------------------------------- | -------------------------------------------------------------------------------- |
| Format                                                                    | Choose the format of the data, with possible values of json or fb (flat buffer). |
| Topic                                                                     | Select the specific device and tag from which data will be collected.            |
| Ignore Failed Data (Manufacturing  Connect Edge version 3.11.0 and later) | Select to ignore data with the output `success=false`.                           |
| Ignore Null Value (Manufacturing  Connect Edge version 3.11.0 and later)  | Select to ignore data with the output `value=null`.                              |

![](https://api.archbee.com/api/optimize/SSUUxKZUk9bFTEPNn_6Zo/eIiNoVTTYlWF7j2Xb4Qlq_image.png "DataHub Subscribe parameters")

# Generator Processors

## Generator Overview

- Simple generator for testing, use **t** as the variable.

## Generator Parameters

| **Parameters**       | **Details**                                                                                                                                       |
| -------------------- | ------------------------------------------------------------------------------------------------------------------------------------------------- |
| Amplitude Multiplier | Specify the amplitude multiplier for the generated signal.                                                                                        |
| Formula              | Choose the supported math functions for generating the signal, such as sin, cos, tan, power, sqrt, log, exp, or abs.                              |
| Generator Type       | User defined signal generation or pre-defined generation.                                                                                         |
| Periodicity          | Define the periodicity of the signal in seconds.                                                                                                  |
| Strength             | Specify the strength of the simulated wave approximation, with the maximum value being 10.                                                        |
| Timer Interval       | Set the timer in milliseconds. If no event occurs, this timer is used to keep displaying the output continually. Enter zero to disable the timer. |

![](https://api.archbee.com/api/optimize/SSUUxKZUk9bFTEPNn_6Zo/NgzaNpvSf-IZGz6Kk2w7I_image.png "Generator parameters")