title: Inputs
slug: manufacturing-connect-edge-v2/inputs
docTags: 
createdAt: 2024-08-08T21:49:21.715Z
---

The multiple **Input&#x20;**&#x70;rocessors help you calculate the statistical properties of the data from the PLC machines.

# Inputs Overview

Use one of the following processors for your inputs:

- **Inputs Average&#xA0;**&#x67;ives you the average of the inputs values in the Flow.
- **Inputs Maximum&#xA0;**&#x67;ives you the maximum value between the inputs in the Flow.
- **Inputs Minimum&#xA0;**&#x67;ives you the minimum value between the inputs in the Flow.
- **Inputs Sum&#xA0;**&#x61;dds all the inputs values in the Flow.

The following information describes these processors:

- For **Field Name**, you can enter the field name for which you want to apply the function. The field name must be available in all the inputs. For example, **value&#xA0;**&#x6F;r **downtime**.
- For **Processing Type**, you can select from **float**, **signed&#xA0;**(signed integer) or **unsigned&#xA0;**(unsigned integer).
- Connect the inputs to the function using the **values&#xA0;**&#x63;onnection. The values connection acts as a time synchronizer.
- Connect the function to the output using the **events&#xA0;**&#x63;onnection.

# Inputs Parameters

| **Parameters**     | **Details**                                                                                        |
| ------------------ | -------------------------------------------------------------------------------------------------- |
| Processing Type    | Data type of the value being processed.<br />&#xD;                                                 |
| Field Name         | Usually left unchanged. Use it if incoming is message type, and/or non-default "value" field name. |
| Pass Through Value | The Pass Through Value parameter enables you to specify how anomalous data should be handled.      |

![](https://api.archbee.com/api/optimize/SSUUxKZUk9bFTEPNn_6Zo/NtS0pUehKmd9cj3hL9F-F_image.png "Inputs Average")

![](https://api.archbee.com/api/optimize/SSUUxKZUk9bFTEPNn_6Zo/Z3OOI1zZL314YvPyqRs8k_image.png "Inputs Maximum")

![](https://api.archbee.com/api/optimize/SSUUxKZUk9bFTEPNn_6Zo/Z3OOI1zZL314YvPyqRs8k_image.png "Inputs Maximum parameters")

![](https://api.archbee.com/api/optimize/SSUUxKZUk9bFTEPNn_6Zo/T3Yb3cAdF84lKjpAT1EOy_image.png "Inputs Sum parameters")

:::hint{type="info"}
**Note:&#x20;**&#x57;hen creating an analytics flow with *Inputs&#x20;*&#x70;rocessor, refer the [Use the Inputs Processor Function](docId\:mHWv9hcBtrZOqTXPza8u3) guide for more details.
:::