title: Manufacturing Connect Edge 3.16.10
slug: manufacturing-connect-edge-v2/manufacturing-connect-edge-31610
docTags: 
createdAt: 2025-07-18T16:15:40.992Z
---

Release Date: July 16, 2025

Review the current list of [Limitations](docId\:vX2EdS4PWKzLyJlAypZlV).

## Enhancements and Improvements

| Description                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                    |
| ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------ |
| **DeviceHub:**<br />* We've added support for additional tags for the Torque Tool Ethernet (Gen1) driver. The following tags (string) are now supported: `GAS_STATUS`, `GAS_TPS_STATUS`, `GAS_GLOBAL_ID`, `GAS_GLOBAL_VERSION`, and `GAS_LOCAL_VERSION`.
* The Siemens S7 driver now supports defining a maximum Protocol Data Unit (PDU). This enables you to adjust the PDU limit in cases where the driver requests data with a PDU that exceeds the limit of a PLC.
* Timestamps for data received by Manufacturing Connect Edge now use time from the Manufacturing Connect Edge host rather than of the remote server. This ensures that data has the correct timestamp. |
| **Integrations:**<br />* A validation action has been added when deleting an integration. Now you must enter the connector name to confirm the connector that you are deleting. This matches the behavior for deleting a device in DeviceHub for a consistent user experience.                                                                                                                                                                                                                                                                                                                                                                                                 |
| **System Settings:**<br />* You can now update Maximum Transmission Unit (MTU) settings in the UI in **System** > **Network** > **Interfaces**. Change MTU settings to resolve network communication issues, for example between Manufacturing Connect Edge and Manufacturing Connect.                                                                                                                                                                                                                                                                                                                                                                                         |

## Resolved Issues

| Description                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                    |
| ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------ |
| **DeviceHub:**<br />* Fixed issue where the Keyence Nano Ethernet (Gen1) driver failed to write data to certain bit registers, for example to EM\_bit, MR, B, and others.
* Fixed issue where a tunnelling connection device with Emerson DNP3 with FB Extensions driver failed to reconnect after the device was rebooted.
* Fixed issue where data values became associated with the wrong tags when a network issue, such as a disconnection, occurred with device connected with the Mitsubishi Q/L Ethernet driver.
* Fixed issue that occurred with S7 CommPlus drivers where UDTs and FBs do not share unique ID space. |
| **Digital Twins:**<br />* Fixed issue where a "static attribute key is not unique operation not permitted" error occurred when updating a model containing dynamic and static attributes with the same name.                                                                                                                                                                                                                                                                                                                                                                                                                   |
| **Marketplace:**<br />* Fixed issue where changes to a virtual machine's IP address in Manufacturing Connect were not reflected in Edge devices associated with Manufacturing Connect Edge.                                                                                                                                                                                                                                                                                                                                                                                                                                    |
| **System:**<br />* Fixed issue the support chat box was not available due to a change in Zendesk Content Security Policy (CSP) requirements.                                                                                                                                                                                                                                                                                                                                                                                                                                                                                   |