title: Manufacturing Connect Edge 3.16.11
slug: manufacturing-connect-edge-v2/manufacturing-connect-edge-31611
docTags: 
createdAt: 2025-08-20T14:08:36.069Z
---

Release Date: August 13, 2025

Review the current list of [Limitations](docId\:vX2EdS4PWKzLyJlAypZlV).

## Enhancements and Improvements

| Description                                                                                                                                                                                                                                                                            |
| -------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- |
| **System:**<br />* With low network quality, remote access connections occasionally disconnected and failed to reconnect automatically.&#xA;Now you can use the new **Reload WG** button in **System** > **Activation** > **Cloud Activation** to create a remote access tunnel again. |
| **DeviceHub:**<br />* With the OPC UA Client Advanced driver, now the `timestamp` in tag payloads reflects the OCP UA `serverTimestamp` when **Driver Mode** is set to Subscription and **Additional Parameters** are enabled.                                                         |

## Resolved Issues

| Description                                                                                                                                                                                                                                                                                                                                                                                                                       |
| --------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- |
| **DeviceHub:**<br />* Implemented a request validation to ensure that the correct data is read from devices for the Keyence Nano Ethernet (Gen1) driver.
* Fixed issue where the Emerson DNP3 with FB Extension driver did not reconnect after power cycling a device when the polling interval is poll once.
* Fixed issue where data was truncated when read into DeviceHub using the AB CompactLogix Ethernet Advanced driver. |
| **System:**<br />* Fixed issue where an OPC UA server would not start on a Docker instance running on an ARM processor.
* Fixed issue with updating stopped containers in Manufacturing Connect. In this case, two containers were created (containing the original and new application) when updating a stopped application. Now only one container is created.                                                                  |