Limitations
2 min
The following limitations have been identified. When they are resolved, they will be reported in the latest Product Updates under Resolved Issues.
DeviceHub:
- The following tag formula operators cannot be used in tags on certain drivers: **(exponent), //(floor division), &(bitwise and), |(bitwise or), ^(bitwise xor), ~(bitwise not), <<(bit left shift), >>(bit right shift), &&(logical and), ||(logical or), and !(logical not). As a workaround, use analytics or flows to perform these operations. The following drivers are affected:
- BACnet: BacnetIP
- Beckhoff: Beckhoff TwinCAT2/3 Ethernet Absolute, Beckhoff TwinCAT3 Ethernet Symbolic
- Fanuc Corporation: Fanuc CNC Ethernet
- Heidenhain: Heidenhain 530 Ethernet, Heidenhain 640 Ethernet
- IEC: IEC61850 MMS Client
- OPC UA: OPC UA Client Advanced
- DeviceHub user role permissions cannot be modified after they are saved. As a workaround, remove and recreate the role.
- The Heidenhain 640 Ethernet driver does not read error information correctly.
Analytics:
- TensorFlow processor models are not checked to confirm that they load or that their Input/Output operation names exist, so a mismatch appears only as a load error when the source is enabled. As a workaround, run saved_model_cli show --dir <model_dir> --all to confirm the exact, case-sensitive operation names from a single signature before you configure the processor.
- FileReader processor is unable to read files that are generated from Flows Manager. As a workaround, in Flows use the exec node to run chmod commands to update file and directory access.
- The first flow created in Flows Manager cannot be stopped or restarted in Safe Mode.
- The Database Batch Input processor stops sending rows on later runs, even when the rows match the query.
Integration:
- Updating the Bulk Insert Count from 0 to any other value causes connectors to enter a failed state.
- A bulk operation limit of 1000 exceeded error message displays when performing a bulk edit on less than 100 subscriptions.
- The Throttling limit setting on connectors does not reduce the rate at which data is written to the destination.
- After a temporary error, the Snowflake Snowpipe Stream connector moves to a failed state and does not retry. As a workaround, disable and re-enable the connector.
- Deleting a connector in a failed state through the API can leave its card on the Integration page. As a workaround, refresh the page.
- During a MongoDB outage, the MongoDB v4+ connector logs that messages were dropped, even though the data is kept and delivered when MongoDB is reachable again. You can ignore this log message.
- CSV topic import on the Topics page accepts topic names that end with a dot, although the UI and templates reject them. As a workaround, remove trailing dots from topic names before you import them.
- The edge_cc_messages_processed metric on the connector metrics endpoint (/cc/metrics) stays at 0 for Gen 2 connectors, even while they are connected and delivering data. Data delivery and the Integration dashboard are not affected, and Gen 1 connectors report correctly. As a workaround, use the Integration dashboard or the destination system to track Gen 2 connector throughput. The edge_cc_status metric still reports the connection state correctly.
OPC UA:
- When a template is applied to a Manufacturing Connect Edge device whose OPC UA server starts with an empty hierarchy, a device from the template may not be served. As a workaround, restart the OPC UA server after you apply the template.
System:
- The snapshots API accepts a duplicate snapshot label. As a workaround, use unique labels when you create snapshots.
- The Apply Template dialog accepts parameter values that the server then rejects, so the error appears only after you apply the template. As a workaround, check parameter values against the template definition before you apply the template.
- Importing a template with multiple connectors fails when a configuration issue occurred with one component.