Fixed missing empty metadata in payloads for the following drivers:
Fixed issue with the incorrect timestamp included in payloads for the Emerson DNP3 Ethernet driver.
Fixed issue with the OPC UA Client Advanced driver generating a Could not load certificate or private key from PKI after upgrading the database.
Fixed issue with the connection configuration for the Enron Modbus driver.
Fixed issue with the auto-scrolling functionality on the Logs screen.
Fixed issue with drivers not reading tag data quickly enough.
Fixed issue of History registers reading null for opcode requests of more than 60 points.
Fixed issue with tag addresses for Gen1 drivers being incorrectly rejected. Address validation is no longer enabled for tag addresses.
Fixed issue with the AB CompactLogix Ethernet Advanced driver not being able to browse UDT tags.
Fixed issue with not being able to enter a tag address that ends in 8 or 9.
Fixed issue with duplicate topics being created for tags with underscore “_” in the tag name.
Fixed the following issues with the FB107 Ethernet driver:
Fixed issue with tags timing out and not sending NATS messages for the DNP3 Ethernet driver.
Fixed issue with the Alarms tag type not parsing correctly with the ROC800 Ethernet driver.
Fixed issue with the CompactLogix Ethernet Advanced driver using the "TagName" parameter instead of "Name" to poll data.
Fixed issue with the Siemens S7 driver crashing when an incorrect tag address is configured.
Fixed issue with the system hanging when importing a large number (3000+) of tags.
Fixed issue with being able to create duplicate topic names with tags that have similar names, but one uses a hyphen and another uses an underscore (for example, C2-1 and C2_1 creates one topic (C2_1) for both tags).
Fixed issue with the BACnetIP driver showing a connected status even though the ethernet cable is disconnected.
Fixed issue with the Fanuc CNC Ethernet (Gen1) driver not being able to read values from the X, Y, and Z axes.
Fixed issue with not being able to configure decimal-point values for the Polling Interval parameter.
Fixed issue with DeviceHub metrics displaying an incorrect status for Device Online Status.
Fixed issue with the Modbus TCP (Gen2) driver displaying an incorrect tag status.
Fixed issue with the Watchdog option not being enabled by default after upgrading from version 3.5.6.
Fixed issue with not being able to configure positive float values for tag poll intervals.
Fixed issue with devices showing a polling status for several minutes when visiting the page for the first time.
Fixed issue with the format of OpCode 7 values for the Emerson FB107 driver.
Fixed issue with not being able to manually change the tag data type for the Euromap 63 driver.
Fixed issue with all tags not being selected when using Browse Tags, selecting tags, using search to filter the results, and then selecting additional tags.
Fixed issue with tag formulas not functioning properly for Manufacturing Connect Edge version 3.11.1 when trying to divide the tag value.
Fixed issue that was causing increased CPU and memory usage over time with some DeviceHub devices.