title: MTConnect Ethernet (Gen1.3)
slug: manufacturing-connect-edge/mtconnect-ethernet-gen13
docTags: 
createdAt: 2022-07-04T16:09:33.000Z
---

Review the following information for setting up and configuring the MTConnect Ethernet (Gen1.3)&#x20;driver.&#x20;

# Manufacturing Connect Edge Compatible Series&#x20;

| Compatibility parameter      | Compatible items                                                          |
| ---------------------------- | ------------------------------------------------------------------------- |
| **Driver type**              | Ethernet                                                                  |
| **Validated devices/series** | Devices that support the [MTConnect](https://www.mtconnect.org/) standard |

To set up and configure this device in Manufacturing Connect Edge, you will need to do the following:

- Step 1: Set up and Configure the PLC Device
- Step 2: Set up the PLC Device in Manufacturing Connect Edge DeviceHub
- Step 3: Configure the List of Registers

# Step 1: Set up and Configure the PLC Device

If the device is configured for Ethernet access, find its network parameters. Otherwise, use PLC software on your computer to configure your device for Ethernet access.

# Step 2: Set up the PLC Device in Manufacturing Connect Edge DeviceHub

Configure the following parameters when you [Connect a Device](docId\:RFVIJdxz7DBAd8mwbismA) with this driver. Update default values to the specific set up of your device.&#x20;

| Parameter           | Value                                        |
| ------------------- | -------------------------------------------- |
| **Type**            | MTConnect Ethernet&#xD;<br />&#xD;           |
| **Driver**          | MTConnect Ethernet (Gen1.3)                  |
| **Network Address** | The device address you defined during Step 1 |
| **Port**            | 47808                                        |

# Step 3: Configure the List of Registers

When you [Add a Tag](docId\:h5heqIcXrCY3NCH9KBg9I) to the connected device, select the name **R** and value type **raw**, and then configure the remaining parameters.&#x20;

You can also browse for tags to add to this device. See [Browse Tags](docId\:OLXXOdRwNLM-IkP2gPS-4).

## Tag Parameters

- **Name**: Select **R**.
- **Value Type**: Select **raw**.&#x20;
- **Polling Interval**: Enter a value in seconds.&#x20;
- **Tag Name**: Enter a name.&#x20;
- **Description** (Optional): Enter a description for the tag. &#x20;
- **Tag Formula**: Enter a formula for the tag to process the generated data. Two variables are permitted: `value` (current tag value) and `timestamp` (current tag UNIX time in milliseconds). The following math functions are available:
  - sin
  - cos
  - sqrt
  - tan
  - power: power(`x`) performs the operation `10^x`.
  - log: log(`x`) is the natural logarithm (the logarithm is in base `e`).&#x20;
  - exp: exp(`x`) performs the operation `e^x`.
- **Only Publish on Change of Value**: Select the checkbox to customize NATS messages to be published only when the *value&#x20;*&#x70;arameter changes from a previous value to a new one. *Change of Value* only applies to boolean, numeric (such as int or float), and simple string data types. It does not apply to complex types, such as JSON or array. Poll-once topics will not be affected by *Change of Value* settings. These topics will still only see a single message.&#x20;
- **Meta Data**: Metadata summarizes basic information about data. This feature allows you to define key-value pair data for the device output payload later on. It can then be used to find, use, and reuse particular instances of data.&#x20;

:::hint{type="info"}
**Note**: If you use special characters in meta data key names, the special characters are replaced with underscore characters in the payload. This can cause two key names to be combined into one. For example, configuring the key names a\*\*b and a&\&b will cause only one key name to be created (a\_\_b).&#x20;
:::