Quickstart Guide
...
Industrial Systems Connection ...
Profinet

Profinet Acyclic Turck

6min
review the following information for setting up and configuring the profinet acyclic turck driver manufacturing connect edge compatible series compatibility parameter compatible items driver type ethernet validated devices/series turck tben l5 8iol to set up and configure this device in manufacturing connect edge, you will need to do the following step 1 set up and configure the plc device step 2 set up the plc device in manufacturing connect edge devicehub step 3 configure the list of registers step 1 set up and configure the plc device if the device is configured for ethernet access, find its network parameters otherwise, use software on your computer to configure the device for ethernet access step 2 set up the plc device in manufacturing connect edge devicehub configure the following parameters when you connect a device docid\ rfvijdxz7dbad8mwbisma with this driver update default values to the specific setup of your device parameter value type profinet driver profinet acyclic turck network address the device address you defined in step 1 network port 34964 refer to the following table for a description of the registers the driver also supports two optional application profiles profidrive and profienergy register type description generic data records reads generic data records enter the record index as the tag address i\&m records reads identification & maintenance records enter the i\&m record index as the tag address profile profidrive profidrive is the standard profile for drive technology in the connection of drives and encoders via profinet io enter the profidrive pnu parameter as the tag address profile profienergy profienergy is a manufacturer and device neutral profile for energy management with profinet enter the profienergy measurement id as the tag address this driver only supports reading tag values step 3 configure the list of registers when you add tags docid\ ioanzd2awqnkuppgee3eh to the connected device, refer to the following register table and tag parameters refer to the following additional resources device and tag metadata use case docid\ f b720nivllber44rfyhn tag formula variables docid\ pwd 7p kzjxkt pyawaow register table name value types address format min address max address description record auto, json, hex, int8, int16, int32, uint8, uint16, uint32, float32, string dddd 0 65535 data records i\&m auto, json, hex dddd 0 65535 identification & maintenance profidrive auto, hex, bool, int8, int16, int32, int64, uint8, uint16, uint32, float32, string, bool\[], int16\[], int32\[], uint16\[], uint32\[], float32\[] dddd 0 65535 acyclic access to parameters (pnu) profienergy auto, float32 dddd 0 65535 profienergy tag parameters name select a register name from the drop down list the available options depend on the names in the register table value type select a data type from the drop down list the available options depend on the register name selected polling interval enter a value in seconds this determines how often the tag should poll the register for data tag name enter a name for the tag description (optional) enter a description for the tag address enter a tag address the value must in the decimal format, within the allowed min/max range omit the leading zeros the device might use the decimal (d), hexadecimal (h), or octal (o) address format see the register table at the bottom of the dialog box for bit tags, append the bit address without the bit separator the lowercase letters in the address format indicate how many digits you should enter in the bit address count enter the number of register values to read a count higher than 1 will generate an array of values from the address value configured and respective subsequent address values slot enter the slot number (0 32767) subslot enter the subslot number (0 41215) tag formula enter a formula for the tag to process the generated data two variables are permitted value (current tag value) and timestamp (current tag unix time in milliseconds) the following math functions are available sin cos sqrt tan power power( x ) performs the operation 10^x log log( x ) is the natural logarithm (the logarithm is in base e ) exp exp( x ) performs the operation e^x only publish on change of value select the checkbox to customize nats messages to be published only when the value parameter changes from a previous value to a new one change of value only applies to boolean, numeric (such as int or float), and simple string data types it does not apply to complex types, such as json or array poll once topics will not be affected by change of value settings these topics will still only see a single message meta data metadata summarizes basic information about data this feature allows you to define key value pair data for the device output payload later on it can then be used to find, use, and reuse particular instances of data note if you use special characters in meta data key names, the special characters are replaced with underscore characters in the payload this can cause two key names to be combined into one for example, configuring the key names a b and a&\&b will cause only one key name to be created (a b)