Roc800 Ethernet
Review the following information for setting up and configuring the Roc800 Ethernet driver.
Manufacturing Connect Edge Compatible Series
Compatibility parameter | Compatible items |
|---|---|
Driver type | Ethernet |
Validated devices/series |
To set up and configure this device in Manufacturing Connect Edge, you will need to do the following:
- Step 1: Set up and Configure the PLC Device
- Step 2: Set up the PLC Device in Manufacturing Connect Edge DeviceHub
- Step 3: Configure the List of Registers
Step 1: Set up and Configure the PLC Device
If the device is configured for Ethernet access, find its network parameters. Otherwise, use Emerson software V2.55 on your computer to configure the device for Ethernet access.
Step 2: Set up the PLC Device in Manufacturing Connect Edge DeviceHub
Configure the following parameters when you Connect a Device with this driver. Update default values to the specific set up of your device.
Parameter | Value |
|---|---|
Type | Emerson |
Driver | Roc800 Ethernet |
Network Address | The device address you defined in Step 1 |
Network Port | 4000 |
Operator ID | LOI |
Device Address | 240 |
Device Group | 240 |
Host Address | 239 |
Host Group | 1 |
Step 3: Configure the List of Registers
When you Add Tags to the connected device, refer to the following register table and tag parameters. You can also Search for Pre-defined Device Tags for this device.
Refer to the following additional resources:
Register Table
Name | Value Types |
|---|---|
OP | JSON, HEX |
PT | JSON, HEX, AC3, AC7, AC10, AC12, AC20, AC30, AC40, INT8, INT16, INT32, UINT8, UINT16, UINT32, FL, DBL, TLP, TIME |
History | JSON |
Alarms | JSON |
Events | JSON |
Tag Parameters
- Name: Select a register name from the drop-down list. The available options depend on the names in the register table.
- Value Type: Select a data type from the drop-down list. The available options depend on the register name selected.
- Polling Interval: Enter a value in seconds. This determines how often the tag should poll the register for data.
- Tag Name: Enter a name for the tag.
- Description (Optional): Enter a description for the tag.
- Opcode: Select the Opcode to use.
- Tag Formula: Enter a formula for the tag to process the generated data. Two variables are permitted: value (current tag value) and timestamp (current tag UNIX time in milliseconds). The following math functions are available:
- sin
- cos
- sqrt
- tan
- power: power(x) performs the operation 10^x.
- log: log(x) is the natural logarithm (the logarithm is in base e).
- exp: exp(x) performs the operation e^x.
- Only Publish on Change of Value: Select the checkbox to customize NATS messages to be published only when the value parameter changes from a previous value to a new one. Change of Value only applies to boolean, numeric (such as int or float), and simple string data types. It does not apply to complex types, such as JSON or array. Poll-once topics will not be affected by Change of Value settings. These topics will still only see a single message.
- Meta Data: Metadata summarizes basic information about data. This feature allows you to define key-value pair data for the device output payload later on. It can then be used to find, use, and reuse particular instances of data.
Note: If you use special characters in meta data key names, the special characters are replaced with underscore characters in the payload. This can cause two key names to be combined into one. For example, configuring the key names a**b and a&&b will cause only one key name to be created (a__b).
Supported Opcodes
- 6 - System Configuration
- 7 - Read Real-time Clock
- 8 - Set Real-time Clock
- 10 - Read Configurable Opcode Point Data
- 17 - Set Operator Identification
- 50 - Request I/O Point Position
- 105 - Request Today’s and Yesterday’s Min/Max Values
- 108 - Request History Tag and Periodic Index
- 118 - Request Alarm Data
- 119 - Request Event Data
- 135 - Request Single History Point Data
- 136 - Request Multiple History Point Data
- 137 - Request History Index for a day
- 138 - Request Daily and Periodic History for a Day
- 139 - History Information Data
- 166 - Set Single Point Parameters
- 167 - Request Single Point Parameters
- 180 - Request Parameters
- 181 - Write Parameters
- 204 - Long Request Event Data
- 206 - Read Transaction History Data
Supported Point Types
- 60
- 68
- 71
- 84: HART Extended Point Type
- 85: HART Point Type
- 91: System Variables
- 92
- 93
- 94
- 95: Communication Ports
- 96
- 97
- 98: Soft Point Parameters
- 99: Configurable Opcode Table
- 100
- 101: Discrete Inputs
- 103: Analog Inputs
- 109: System Analog Inputs
- 110: PID Control Parameters
- 111
- 117: Modbus Configuration Parameters
- 118: Modbus Register to TLP Mapping
- 119: Modbus Event, Alarm, and History Table
- 120: Modbus Master Modem Configuration
- 121: Modbus Master Table
- 122
- 123: Security – Group Configuration
- 124: History Segment Configuration
- 125: History Segment 0 Point Configuration
- 126: History Segment 1 Point Configuration
- 127: History Segment 2 Point Configuration
- 128: History Segment 3 Point Configuration
- 129: History Segment 4 Point Configuration
- 130: History Segment 5 Point Configuration
- 131: History Segment 6 Point Configuration
- 132: History Segment 7 Point Configuration
- 133: History Segment 8 Point Configuration
- 134: History Segment 9 Point Configuration
- 135: History Segment 10 Point Configuration
- 136: ROC Clock
- 137: Internet Configuration Parameters
- 138
- 139: Smart I/O Module Information
- 142: History Segment 11 Point Configuration
- 143: History Segment 12 Point Configuration
- 144: Transactional History Configuration Point Type
- 145: Transactional History Point Configuration Point Type
- 196-208
- 210-219
- 230-234