Manufacturing Connect User UI
...
Activation
Activation Configs

Set Up an Activation Configuration

16min

An activation configuration can be configured with limits, license keys, template and/or template variables. These configurations are all entirely optional. Some of these configurations have existing default values while others can be left blank. These configurations are all implemented in the first four steps and can be skipped if no additional customization is needed.

Generating the details for an activation configuration occurs only in Step 6:Save while retrieving the key details are in Step 7: Retrieve Activation Code/URL.

Note: For Manufacturing Connect version 2.17.0 and later, respective activation URLs for Edge devices are automatically updated based on the new domain name. For earlier versions, activation URLs will have to be manually updated.

Before You Begin

  • If you are using a node-locked license, make sure you have a license key for deployment. To get a license key, contact your account executive.
  • If you are using a site-based license, make sure you’ve already applied the license in Manufacturing Connect. See License Server.

Step 1: Configure Limits

After navigating to Edge Management > Activation Configs and clicking the Add (+) icon, you can start configuring the limits.

You have the option of configuring limits, specifically number of edge devices, lease TTL, and expiration date. If no changes are needed, proceed to the next step.

Manufacturing Connect User UI : Activation > Configuration : Activation Config 1/7 Config Limits
Manufacturing Connect User UI : Activation > Configuration : Activation Config 1/7 Config Limits

  • Number of Edge devices: Enter the number of devices that will share the activation code. The activation code (created after saving) can be used for multiple edge device activation.
  • Lease TTL: For identity certificate: enter the number of days the activation code is valid to be used for an Edge device activation.
  • Expiration Date: Select the date on when the activation code will expire. Specifically, when the Manufacturing Connect Edge instances that use this license will need a new activation code.

Step 2: Add Templates

You have the option of applying templates when activating a Manufacturing Connect Edge device. Learn more about Templates.

If the Manufacturing Connect Edge device doesn't need a template, proceed to the next step.

Manufacturing Connect User UI : Activation Configs : Activation Config 2/7 Add Templates
Manufacturing Connect User UI : Activation Configs : Activation Config 2/7 Add Templates


To add at least one template:

  1. From the Template section, click the Add icon. The Template Select dialog box appears.
  2. Select one or more templates from the list, and then click Select. The selected template appears in the Templates list.
Manufacturing Connect User UI : Activation > Configuration : Activation Config 2/7 Template Select
Manufacturing Connect User UI : Activation > Configuration : Activation Config 2/7 Template Select


Step 3: Add Template Variables

You have the option of applying template variables when activating a Manufacturing Connect Edge device. To use template variables, you'll need to Parameterize a Template first.

If the Manufacturing Connect Edge device doesn't need any template variables, proceed to the next step.

Add Template Variables Manually

Manufacturing Connect User UI : Activation > Configuration : Activation Config 3/7 Template Variable : Add Template Variables
Manufacturing Connect User UI : Activation > Configuration : Activation Config 3/7 Template Variable : Add Template Variables


To add at least one template variable manually:

  • From the Template Variables section, click the Add icon. The Add new variable set dialog box appears.

Add Template Variables for All Devices

Manufacturing Connect User UI : Activation > Configuration : Activation Config 3/7 Add new variable set dialog box : All devices
Manufacturing Connect User UI : Activation > Configuration : Activation Config 3/7 Add new variable set dialog box : All devices

  1. From the Add new variable set dialog box, click the Variable set type toggle so it displays All Devices.
  2. Click Add. The Variable set: All devices appears in the Template Variables list.
  3. Click the Add icon next to the variable set. The Variables line items drop down.
  4. In the Variable Name field, enter a variable name.
  5. In the Variable Value field, enter a variable value.

Adding Template Variables for Individual Edge Device

Manufacturing Connect User UI : Activation > Configuration : Activation Config 3/7 Add new variable set dialog box : Per Edge Devices
Manufacturing Connect User UI : Activation > Configuration : Activation Config 3/7 Add new variable set dialog box : Per Edge Devices

  1. From the Add new variable set dialog box, click the Variable set type toggle so it displays Per Edge Device.
  2. In the Host Name field, enter the host name for an edge device. To find host name for an edge device, see Configure the Network Settings' Host Information.
  3. Click Add. The Variable set: per Edge Device: <hostname> appears in the Template Variables list.
  4. Click the Add icon next to the variable set. The Variables line items drop down.
  5. In the Variable Name field, enter a variable name.
  6. In the Variable Value field, enter a variable value.

Adding Template Variables Using .csv File

Multiple template variables can be uploaded using a .csv file. A sample .csv file is available to download for customization.

Manufacturing Connect User UI : Activation Configs : Activation Config 3/7 Template Variable : Upload Template Variables
Manufacturing Connect User UI : Activation Configs : Activation Config 3/7 Template Variable : Upload Template Variables


To add at least one template variable using a .csv file:

  1. From the Template Variables section, click the Upload icon. The Upload variable sets dialog box appears.
  2. (Optional) Click the here link to download a sample .csv file.
  3. Click Select File, navigate to a variable set .csv file, and then click Open. The selected .csv file appears in the File Name field.
  4. Click Upload. The variable sets listed in the .csv file appear in the Variable Sets list.

Step 4: Configure Provision Options

The Manufacturing Connect Edge device can be customized to automatically integrate a PubSub Connector or connect a Simulator device. See Google Cloud Pub/Sub Connector section of Connector Provider Reference Table and Generator for details.

For Manufacturing Connect version 2.12.0 and later, you can apply the default password policy during activation, select the Password Policy checkbox. If there are multiple password policies, the master default password policy that can't be deleted is implemented.

Provision Options section
Provision Options section


After activation, you can update the default password policy for individual edge devices.

Step 5: Configure Advanced Settings

Note: The Advanced Settings feature is available for Manufacturing Connect 2.11.0 and later.

When Manufacturing Connect (MC) connects to a Manufacturing Connect Edge (MCe), it uses Remote Access. Remote Access has a parameter PersistentKeepalive that you can reconfigure on how often to send an authenticated empty packet to a Manufacturing Connect Edge for the purpose of maintaining the MC-MCe connection. By default, Remote Access uses 22 seconds.

Manufacturing Connect User UI : Activation > Configuration : Activation Config 5/7 Advanced Settings: Remote Network Persistent Keepalive Interval
Manufacturing Connect User UI : Activation > Configuration : Activation Config 5/7 Advanced Settings: Remote Network Persistent Keepalive Interval


To set advanced settings, from the Remote Network Persistent Keepalive field, enter a number of seconds between 1-25.

Step 6: Save

Once all the configuration for an Activation Configuration is complete, a save is needed to generate the activation code.

Manufacturing Connect User UI : Activation Configs : Activation Config 6/7 Save
Manufacturing Connect User UI : Activation Configs : Activation Config 6/7 Save


To complete an activation configuration creation:

  1. Click Save. Once saved, the activation code will then be generated at the Activation Code field.

Step 7: Retrieve Activation Code/URL

After a Save is successfully complete, the Activation Code will display underneath the Activation Code section. This code and the Activation URL will be needed when activating a Manufacturing Connect Edge instance.

Manufacturing Connect User UI : Activation Configs : Activation Config 7/7 Retrieve activation code/URL
Manufacturing Connect User UI : Activation Configs : Activation Config 7/7 Retrieve activation code/URL


To retrieve the activation code/URL :

  1. Copy to clipboard the Activation Code. It will be needed for activating a Manufacturing Connect Edge instance.
  2. Copy to clipboard the Activation URL. It will be needed for configuring a Manufacturing Connect Edge instance.

Next Steps

Use the copied Activation Code and Activation URL to Activate an Edge Device.