AB Micro850 (Gen1)
Review the following information for setting up and configuring the AB Micro850 (Gen1) driver.
Compatibility parameter | Compatible items |
---|---|
Driver type | Ethernet |
Validated devices/series | Micro800 When configuring tags for this driver, you must enter the case-sensitive register name exactly as it is defined in the PLC. See the Free Tags section below to learn more. |
To set up and configure this device in Manufacturing Connect Edge, you will need to do the following:
- Step 1: Set up and Configure the PLC Device
- Step 2: Set up the PLC Device in Manufacturing Connect Edge DeviceHub
- Step 3: Configure the List of Registers
If the device is configured for Ethernet access, find its network parameters. Otherwise, follow the steps below.
To configure your device:
Note down the following information and refer to it when needed.
- Launch RSLinx Classic, and connect the device to a PC using USB cable. The device is added to the browser.
Right-click the device and then click Module Configuration.
From Port Configuration, set up the device Ethernet parameters.
Create an AB_ETHP-1 driver. Select an adapter on the same subnet as the device. If you cannot find it in the local subnet, select Remote Subnet.
- Launch CCS, Connected Component Workbench.
Click the Discover icon to browse the device.
Double-click the device.
Parameter | Value |
---|---|
Type | Allen-Bradley |
Driver | AB Micro850 (Gen1) |
Network address | The device address you defined in Step 1 |
Port | 44818 |
Slot Number | 0 |
- bool
- sint
- int
- dint
- real
- lint
- byte
- word
- dword
- lword