Euromap63 (Gen1)
Review the following information for setting up and configuring the Euromap63 (Gen1) driver.
Compatibility parameter | Compatible items |
---|---|
Driver type | File-based |
Validated devices/series | Euromap 63 The Euromap 63 standard defines the data exchange with injection molding machines through files. When configuring tags for this driver, you must enter the case-sensitive register name exactly as it is defined in the PLC. See the Free Tags section below to learn more. |
The Euromap63 (Gen1) driver supports the following commands in the specification.
Euromap63 command | Use in Manufacturing Connect Edge |
---|---|
GETID | Browses available tags. |
REPORT | Retrieves tag values from the injection molding machine. |
To set up and configure the Euromap63:
- In Manufacturing Connect Edge, follow the steps to Mount External Storage and configure the following parameters.
- Mount Point Name: Enter the name of the shared folder you created previously.
- Share: Enter the share name in the following format: //[IP address of the PC running the simulator]/[shared folder name]. For example: //192.168.53.34/Euromap63folder.
- Read Only: Uncheck the checkbox.
- Username: Enter the Linux Samba username you configured.
- Password: Enter the password for the Linux Samba username you configured.
- In Manufacturing Connect Edge, follow the steps to Connect a Device and configure the following parameters. Configure other parameters as needed.
- Device Type: Select Euromap63.
- Driver Name: Select Euromap63 (Gen1).
- Path: Enter the path of the shared folder in the following format: /data/[shared folder name]. For example: /data/Euromap63folder.
If you need to manually Add Tags to the device, refer to the following tag parameters and available value types.
Refer to the following additional resources:
This driver doesn't have a list of available register names in the DeviceHub Add Tag form.
To add tags, you must enter the case-sensitive register name exactly as it is defined in the PLC.
A Connected status for the device won't display until a tag with a correct register name is created.
- int
- float
- int64
- float64
- string