Product Features
...
OPC UA Server
Management
Manage the OPC UA Server
2min
You can manage the OPC UA Server by navigating to OPC > Management.
If you are using the Docker version of Manufacturing Connect Edge and having issues connecting to the OPC UA server, refer to Issues Connecting to OPC UA Server.
Refer to the following OPC UA Server management options.
OPC UA Server management options
[1] Start and Stop OPC UA Server: Before you start the OPC UA Server, make sure you do the following:
- Configure the OPC UA Server. Refer to the callout below for more information.
- Enable at least one OPC UA policy.
- Configure OPC UA authentication.
After starting the OPC UA Server, you have the option of stopping it.
[2] Restart OPC UA Server: Restarting the server returns it to its original configuration.
[3] Configure OPC UA Server: To configure the OPC UA Server, enter the details for the server:
- Host: Enter the OPC UA host IP address.
- Port: Enter the port number 4840.
- Allow Nodes Under Root: If this option is selected, the OPC UA hierarchy will start under the root folder. If unselected, the OPC UA hierarchy will start under the Objects node.
[4] Click the View icon to review logs for the server.