- Improved the DeviceHub tag browsing experience with better default layouts, clearer columns, and new task controls (including start/stop and delete confirmation) for easier task management.
- Mitsubishi
Added support to Mitsubishi FX3G Binary Ethernet (Gen1.3) driver for:
- Additional registers: X, Y, M, T, C, SM, S, R, SD, D, CV, CV2, TV
- String file registers: DSH/DSL and RSH/RSL
- bit, word, dword, float, and string types
- ODVA
Improved the CIP Ethernet driver’s browsing so that assemblies, such as specific instances in Assembly class 04, are now correctly discovered and accessible.
- OPC UA
Improved OPC UA Advanced driver browsing by adding a Default Root browse parameter (with a recommended default) and simplifying related device settings.
- Siemens
Siemens TI505 Ethernet (Gen1.3)
- Extended support for WX, WY, C/CR, V, K, TCP/TCC, STW, DSP/DSC, DCP/DCC registers
- Includes .bit and string register variants
- Broader address range and data type coverage
- Toyopuc
The Toyopuc Ethernet Driver was renamed to Toyopuc Ethernet.
- The Toyopuc Ethernet (renamed ) and Keyence Nano Ethernet drivers are improved with expanded device and protocol support. Improvements include:
- Array read/write for all register types
- Improved byte order and string handling (Unicode and Shift-JIS support)
- Multi-point reads and FL-net linking (up to four layers)
- New Max Request Size setting for performance tuning
- Added write response topic support for Allen‑Bradley, Emerson ROC/FB107, Emerson DNP3, Mitsubishi, Modbus, Omron, Siemens, MQTT Client, Generator, and SNMP Manager drivers.
- Improved the DeviceHub REST driver so it can correctly parse JSON responses even when the Content-Type header is missing or set to an unknown value. This ensues that array values are read reliably.
|