Mitsubishi FX3G Binary Ethernet (Gen1)
Review the following information for setting up and configuring the Mitsubishi FX3G Binary Ethernet (Gen1) driver.
Compatibility parameter | Compatible items |
---|---|
Driver type | Ethernet |
Validated devices/series | MELSEC-F |
To set up and configure this device in Manufacturing Connect Edge, you will need to do the following:
- Step 1: Set up and Configure the PLC Device
- Step 2: Set up the PLC Device in Manufacturing Connect Edge DeviceHub
- Step 3: Configure the List of Registers
Note: Only one connection is allowed per port defined in the PLC. See the steps below to view and edit the open ports on the PLC.
If the device is configured for Ethernet access, find its network parameters. Otherwise, follow the steps below.
To configure your device:
Note down the following information and refer to it when needed. Device: Mitsubishi FX3GE-24M Communication I/F: Ethernet. Refer to the following figure.
- Connect the device to your pc using USB and launch the GX Works 2 v1.560J software.
- Click Online > Read from PLC.
- Select PLC series.
- Set up the connection.
- Click Connection Test.
- From the Navigation panel, click Parameter > PLC Parameter > Ethernet Port.
- From the Navigation panel, click Connection Destination > connection1.
- Double-click PLC Module , click Search for FXCPU on network, and then select the target device.
- Click Connection Test.
Parameter | Value |
---|---|
Type | Mitsubishi |
Driver | Mitsubishi FX3G Binary Ethernet (Gen1) |
Network Address | The device address you defined in Step 1 |
Port | 5001 |
Name | Value Type | Address Format | Min Address | Max Address | Description |
---|---|---|---|---|---|
X | bit | DDD | 0 | 255 | Input Relay |
Y | bit | DDD | 0 | 255 | Output Relay |
M | bit | DDDD | 0 | 7999 | Internal Relay |
T | bit | DDD | 0 | 511 | Timer Contacts |
C | bit | DDD | 0 | 255 | Counter Contacts |
SM | bit | DDDD | 8000 | 8511 | Source Int. Relays |
S | bit | DDDD | 0 | 4095 | Step Relays |
R | word | DDDDD | 0 | 32767 | File Register |
SD | word | DDDD | 8000 | 8511 | Service Data Register |
CV2 | word | DDD | 200 | 255 | Counter Value |
D | word | DDDD | 0 | 7999 | Data Registers |
CV | word | DDD | 0 | 199 | Counter Value |
TV | word | DDD | 0 | 511 | Timer Value |