Review the following information for setting up and configuring the Panasonic FP Ethernet (Gen1) driver.

Manufacturing Connect Edge Compatible Series

Compatibility parameter

Compatible items

Driver type

Serial

Validated devices/series

FP2 FP7 FP-X

To set up and configure this device in Manufacturing Connect Edge, you will need to do the following:

  • Step 1: Set up and Configure the PLC Device
  • Step 2: Set up the PLC Device in Manufacturing Connect Edge DeviceHub
  • Step 3: Configure the List of Registers

Step 1: Set up and Configure the PLC Device



To configure your device:

  1. Note down the following information and refer to it as needed. Device: Panasonic FP2SH-60K Communication I/F: RS232
  2. Launch Control FPWIN Pro7 v7.2.3.0 software and click Online > Communication parameters.
  3. Set up communication parameters.
  4. Click Online mode.

Step 2: Set up the PLC Device in Manufacturing Connect Edge DeviceHub



Parameter

Value

Type

Panasonic

Driver

Panasonic FP Serial (Gen1)

Communication Port

Local Serial connection file path

Data Bits

8

Baud Rate

19200

Parity

Even, Odd, None

Stop Bits

1

Station ID

1



Name

Value Type

Address Format

Min Address

Max Address

Description

X

bit

DDDDdd

0

999915

Input bit

Y

bit

DDDDdd

0

999915

Output bit

R

bit

DDDDdd

0

999915

Internal Relay

L

bit

DDDDdd

0

9999

Link Relay

L_Bit

bit

DDDDdd

0

999915

 

T

bit

DDDD

0

9999

Timer

C

bit

DDDD

0

9999

Counter

SV

word

DDDD

0

9999

Timer/Counter Set Value

EV

word

DDDDD

0

65535

Timer/Counter Elapsed Value

DT

word

DDDDD

0

262143

Data Register

LD

word

DDDD

0

8447

Link Register

WX

word

DDDD

0

9999

Input

WY

word

DDDD

0

9999

Output

WR

word

DDDD

0

9999

Internal Relay

WL

word

DDDD

0

9999

Link Relay

FL

word

DDDDD

0

99999

File Register