Quickstart Guide
...
Siemens
Gen 1 Drivers

Siemens S7-200 Ethernet (Gen1)

5min

Review the following information for setting up and configuring the Siemens S7-200 Ethernet (Gen1) driver.

Manufacturing Connect Edge Compatible Series

Compatibility parameter

Compatible items

Driver type

Ethernet

Validated devices/series

S7-200

To set up and configure this device in Manufacturing Connect Edge, you will need to do the following:

  • Step 1: Set up and Configure the PLC Device
  • Step 2: Set up the PLC Device in Manufacturing Connect Edge DeviceHub
  • Step 3: Configure the List of Registers

Step 1: Set up and Configure the PLC Device

If the device is configured for Ethernet access, find its network parameters. Otherwise, use PLC software on your computer to configure your device for Ethernet access.

Step 2: Set up the PLC Device in Manufacturing Connect Edge DeviceHub



Parameter

Value

Type

Siemens

Driver

Siemens S7-200 Ethernet (Gen1)

Network Address

The device address you defined in Step 1

Port

102

Slot

512



Name

Value Type

Address Format

Min Address

Max Address

I

bit, byte, sint, word, int, dword, dint, real

DDo

0

317

Q

bit, byte, sint, word, int, dword, dint, real

DDo

0

317

AI

byte, sint, word, int, dword, dint, real

DD

0

31

AQ

byte, sint, word, int, dword, dint, real

DD

0

31

M_Bit

bit

DDo

0

317

V_Bit

bit

DDDDo

0

20477

S_Bit

bit

DDo

0

287

SM_Bit

bit

DDDo

0

5497

T_Bit

bit

DDD

0

255

C_Bit

bit

DDD

0

255

M

byte, sint, word, int, dword, dint, real

DD

0

31

S

byte, sint, word, int, dword, dint, real

DD

0

31

SM

byte, sint, word, int, dword, dint, real

DDD

0

549

T

dword

DDD

0

255

C

word

DDD

0

255

HC

dword

D

0

5

V

byte, sint, word, int, dword, dint, real, string

DDDD

0

2047