Siemens Sinumerik Ethernet (Gen1)
Review the following information for setting up and configuring the Siemens Sinumerik Ethernet (Gen1) driver.
Compatibility parameter | Compatible items |
---|---|
Driver type | Ethernet |
Validated devices/series |
To set up and configure this device in Manufacturing Connect Edge, you will need to do the following:
- Step 1: Set up and Configure the PLC Device
- Step 2: Set up the PLC Device in Manufacturing Connect Edge DeviceHub
- Step 3: Configure the List of Registers
If the device is configured for Ethernet access, find its network parameters. Otherwise, follow the steps below for Toolbox v4.6.
To configure your device:
- Note down the following information and refer to it when needed. Device: Siemens 808D Advanced M Communication I/F: Ethernet.
Press Set password.
Enter SUNRISE for authorization to configure the device.
- Press Sys Data.
Press Serv displ.
Press Service Network.
Enter the network parameters.
Parameter | Value |
---|---|
Type | Siemens |
Driver | Siemens Sinumerik Ethernet (Gen1) |
Network Address | The device address you defined in Step 1 |
Port | 102 |
Slot | 2 |
Name | Value Type | Address Format | Min Address | Max Address | Description |
---|---|---|---|---|---|
I | bit | DDDDo | 0 | 40957 |
|
Q | bit | DDDDo | 0 | 40957 |
|
M_Bit | bit | DDDDo | 0 | 40957 |
|
V_Bit | bit | DDDDDDDDo | 0 | 100000007 |
|
S_Bit | bit | DDDDo | 0 | 40957 |
|
SM_Bit | bit | DDDDo | 0 | 40957 |
|
T_Bit | bit | DDDo | 0 | 2557 |
|
C_Bit | bit | DDDo | 0 | 2557 |
|
M | byte, sint, word, int, dword, dint, real | DDDDD | 0 | 10239 |
|
S | byte, sint, word, int, dword, dint, real | DDDDD | 0 | 10239 |
|
SM | byte, sint, word, int, dword, dint, real | DDDDD | 0 | 10239 |
|
V | byte, sint, word, int, dword, dint, real | DDDDDDDD | 0 | 10000000 |
|