Quickstart Guide
...
Industrial Systems Connection ...
Yokogawa

Yokogawa FA-M3 Ethernet (Gen1)

6min

Review the following information for setting up and configuring the Yokogawa FA-M3 Ethernet (Gen1) driver.

Manufacturing Connect Edge Compatible Series

Compatibility parameter

Compatible items

Driver type

Ethernet

Validated devices/series

To set up and configure this device in Manufacturing Connect Edge, you will need to do the following:

  • Step 1: Set up and Configure the PLC Device
  • Step 2: Set up the PLC Device in Manufacturing Connect Edge DeviceHub
  • Step 3: Configure the List of Registers

Step 1: Set up and Configure the PLC Device

If the device is configured for Ethernet access, find its network parameters. Otherwise, follow the steps below.

To configure your device:

  1. Note down the following information and refer to it when needed. Device: Yokogawa FA M3 F3SP25-SN Communication I/F: Ethernet. Refer to the following figure.

    Document image
    
  2. Launch WideField3 v3.02 software and create a project with the device model.
  3. Click Tools > Set up Environment.
  4. Configure the network parameters.
  5. Click Online > Connect and verify the connection is successful.

Step 2: Set up the PLC Device in Manufacturing Connect Edge DeviceHub



Parameter

Value

Type

Yokogawa

Driver

Yokogawa FA-M3 Ethernet (Gen1)

Network Address

The device address you defined in Step 1

Port

12289

Station ID

1



Name

Value Type

Address Format

Min Address

Max Address

Description

X

bit

DDDDD

0

71644

Input bit

Y

bit

DDDDD

0

71644

Output bit

I

bit

DDDDD

1

65535

 

M

bit

DDDD

1

9984

 

L

bit

DDDDD

0

78192

 

F

word

DDDDDD

1

524288

 

Z

word

DDDD

1

1024

 

W

word

DDDDD

1

78192

 

V

word

DDD

1

256

 

B

word

DDDDDD

1

262144

 

D

word

DDDDD

1

65535