QuickStart Guide
Activate an Edge Device
Step 4: Verify Edge Device Activation in Manufacturing Connect Edge
2min
After you have approved the activation request in Manufacturing Connect, return to Manufacturing Connect Edge to verify the activation was successful.
The verification includes the following:
- System API key created.
- Identity Certificate created.
- MQTT connector created.
- Google Pub/Sub connector created with custom attribute of mce_hostname. The ability to create custom attributes in the Google Pub/Sub connector will be available in Manufacturing Connect Edge version 3.10.0 and later.
To verify that the activation was successful:
- From the navigation panel, select System > Tokens.
From REST API Keys, verify the creation of a System API key (read only).
- From the navigation panel, select System > Certificates > Identity.
From Identity Certificates, verify the creation of an Identity Certificate issued by Manufacturing Connect.
- From the navigation panel, select Integration.
- Review and confirm one of the following.
- For Manufacturing Connect version 2.11.0 and earlier, confirm that the default MQTT integration connector displays and isn't enabled.
- For Manufacturing Connect version 2.12.0 and later, confirm that two default connectors display: MQTT disabled and Google Cloud Pub/Sub Connector enabled. The Google Cloud Pub/Sub connector should have a custom attribute with a key of mce_hostname and the hostname value, which includes the MAC address.
Proceed to Step 5: Enable the Default Integration Connector.