Manufacturing Connect User UI
...
Edge Devices
Edge Device Details

Metrics

3min

Once an edge device begins communicating with Manufacturing Connect, the metrics of your edge device become available in the Metrics tab.

The tab is divided into two sections:

  • DeviceHub - lists all devices connected to the edge device; shows their status and the number of tags
  • Integration - lists integration connectors defined for the edge device; shows their status, rate, and buffer size

Refer to the following metrics you can refer to on the Manufacturing Connect User UI's Edge Devices Metrics tab.

Edge Devices Metrics
Edge Devices Metrics


Section

Column

Description

[1] Device Hub

Name

The name of the device connected to the edge system.



Tags

The number of tags associated with the device.



Success | Error Rate (msgs/min)

The rate of successful and error messages per minute for each device.



Status

The current status of the device connection.

  • A green dot indicates a device is online.
  • A red dot indicates a device is offline.

[2] Integration

Name

The name of the integration service used by the edge system.



Rate (msgs/min)

The rate of messages per minute processed by the integration.



Buffer Size

The current buffer size of the integration.



Status

The current status of the integration.

  • A green dot indicates online status.
  • A red dot indicates offline status.

Additional Metrics

You can use additional metrics sources to set up an alert based on metrics collected by Manufacturing Connect. The alert can trigger when a variable reaches a specific value or a set/interval of values. Only one metrics rule can be created per alert. See Set Up Alert Triggers for more.

Note: You can set up alert triggers for different metrics of your edge devices in the Triggers section in the Alerts module. Review the Alerts Guides for setting up alert triggers.

Refer to the following table for more information on additional metrics available for alerts template:

Source

Metrics Name

Description / Purpose

Parameters

Integration

Connector disk buffer

Monitor Integration Connector disk buffer, which is used when the connector’s throughput is insufficient to handle all defined tags coming from Edge devices.

  • Target Value in MB
  • Alert Delay in seconds

Integration

Connector online status

Detect unplanned Integration Connector disconnections.

  • Alert Delay in seconds

DeviceHub

DeviceHub (DH) online status

Detect unplanned disconnections of DeviceHub (DH) devices.

  • Alert Delay in seconds

DeviceHub

DeviceHub (DH) device data quality

Monitor the rate of low-quality (i.e., error) messages. A high rate of low-quality messages indicates a problem with either the physical device or the device driver.

  • Target Value in msgs/minute
  • Alert Delay in seconds

Edge Device

Edge Device online status

Detect unexpected disconnections of edge Devices.

  • Alert Delay in seconds

Edge Device

Edge Device license expiration

Detect when the license of an edge device has expired.

  • Target Value in days
  • Alert Delay in seconds

Edge Device

Edge Device free disk space

Monitor the available disk space of an edge device.

  • Target Value in Percentage
  • Alert Delay in seconds

Edge Device

Edge Device memory available

Monitor the available memory of an edge device

  • Target Value in Percentage
  • Alert Delay in seconds

Edge Device

Edge Device CPU Idle

Monitor the CPU usage of an edge device

  • Target Value in Percentage
  • Alert Delay in seconds